Nov 30, 2023
The correct operating procedures for the vacuum emulsifier are as follows:
8. If a problem with the homogenizer is found during operation, the power should be turned off quickly and disassembled for maintenance.
9. When opening the vacuum system, open the vacuum control switch first, and then open the vacuum pipeline valve. When closing, first close the vacuum management valve, then turn off the power supply. When the negative pressure is 0.05mpa to 0.06mpa, open the feed valve to absorb 70% of the water. After absorbing the oil, absorb 30% of the water. And always check whether the filter is complete to prevent debris from entering the emulsification pot to ensure the normal operation of the homogenizer. The vacuum degree in the emulsification pot should not be too high. Generally, it should be between 0.05mpa and 0.06mpa to avoid causing the water to boil.
10. The working machine must be guarded by a dedicated person, and the machine must be stopped when the person is away.
11. Before stopping, first adjust the speed to zero. Press the mixing stop button again.
12. Turn off the power switch, check whether each water valve is closed, and open the vacuum exhaust valve.
13. After discharging the semi-finished product, wash the residue in the pot with warm water and keep the pot clean.
14. Make the motor and pump smooth and tighten the parts that are prone to loosening.
15. Each shift must keep equipment operating status records and routine maintenance records.
Previous: How to quickly address a ball mill blockage?
Next: Instructions for use of vacuum emulsifier for stable operation 1